PID Controller

#include <branes/reflex/control/pid.hpp>

Grade: C (specified and unit-tested) under the building block standard. The V&V plan has the assessment and the path to A.

This is the developer guide: the control law, contracts, and API. The explainer builds the controller up one term at a time, and the deployment guide covers choosing its limits and wiring it into a loop.

branes::reflex::Pid<Real> is a discrete-time PID controller with the refinements a flight controller needs: derivative on measurement, a derivative low-pass filter, integral clamping, conditional-integration anti-windup, and output saturation.

With setpoint rr, measurement yy, error e=r−ye = r - y and sample period Δt\Delta t, each update computes

uk=sat⁡[umin⁡, umax⁡] ⁣(Kpek+Ik−Kdy˙k)u_k = \operatorname{sat}_{[u_{\min},\,u_{\max}]}\!\left(K_p e_k + I_k - K_d \dot{y}_k\right)

Derivative on measurement. The D term uses −y˙-\dot{y} rather than e˙\dot{e}. For a constant setpoint they are equal, but a step in rr produces no derivative kick. The rate is low-pass filtered with time constant τ\tau:

y˙k=τ y˙k−1+Δt yk−yk−1Δtτ+Δt\dot{y}_k = \frac{\tau\,\dot{y}_{k-1} + \Delta t\,\dfrac{y_k - y_{k-1}}{\Delta t}}{\tau + \Delta t}

τ=0\tau = 0 disables the filter. The first update after construction or reset() has no history, so its rate is zero.

Integral. The integral is kept in output units, Ik=Ki∑e ΔtI_k = K_i \sum e\,\Delta t, clamped to [Imin⁡,Imax⁡][I_{\min}, I_{\max}].

Anti-windup (conditional integration). If the unsaturated output exceeds a limit and the error would push it further past that limit, the integral is frozen for that step. If the error would pull the output back into range, it integrates normally. After a long saturation (for example, a setpoint the actuator cannot reach), the loop recovers immediately instead of waiting for a wound-up integral to unwind. The closed-loop test anti-windup recovers quickly from an unreachable setpoint pins this: the loop settles in under 0.2 s, versus ~2.4 s for a naive integrator.

External saturation. A stage after the controller can cut its command, as the mixer does under saturation. The four-argument update(setpoint, measurement, dt, external_saturation) takes the direction of that cut (+1 delivered less than the output, −1 more, 0 not cut) and freezes the integral by the same rule as the controller’s own limits. The cascaded controller feeds it the mixer’s report.

#include <branes/reflex/control/pid.hpp>
using branes::reflex::Pid;
using branes::reflex::PidConfig;
PidConfig<float> cfg;
cfg.kp = 0.8f;
cfg.ki = 2.0f;
cfg.kd = 0.02f;
cfg.output_min = -1.0f; // normalized torque command
cfg.output_max = 1.0f;
cfg.integral_min = -0.3f; // cap the integral's authority
cfg.integral_max = 0.3f;
cfg.derivative_tau = 0.001f; // ~160 Hz derivative filter
Pid<float> roll_rate{cfg};
// In the 8 kHz rate loop:
float torque = roll_rate.update(rate_setpoint, gyro_x, dt);
ConstructionRequires pid_config_valid(cfg): non-negative gains, min <= max for both limit pairs, derivative_tau >= 0. Checked by assert.
updateAlways returns a value in [output_min, output_max]. A non-positive dt is a timing fault: the controller returns its last output and leaves its state unchanged.
resetReturns to the constructed state: zero integral and rate (clamped into range if zero is outside it), unprimed derivative.
Real-timenoexcept, no allocation, constant time, usable in constexpr.

Gains are fixed at construction; there is no setter. To retune, construct a new controller through the lifecycle (Unconfigured → Inactive → Active).

update() trusts the dt it is given. A non-positive dt is a fault, and the controller holds its output and state. A positive dt is always accepted, however long. So when a loop misbehaves after a scheduler problem, the trace of dt next to the output and the integral tells which case it was. The scenario below replays three faults of the kind a scheduler produces.

What does the controller do when its scheduler misbehaves? 1× real time
Command u
Integral term I
Plant output x setpoint
dt passed to update() [s] dt
t = 0.000 s / 0.250 s

Keys (with the player focused): Space play/pause · ← → one sample (Shift: ten) · Home/End · [ ] speed

A PI controller (k_p = 1, k_i = 10) drives a first-order plant toward 0.5 from 20 ms. The plant runs on real time at 1 kHz; the controller is called with the dt its scheduler measured, plotted at the bottom. At 50 ms a duplicated tick passes dt = 0, and at 70 ms the clock steps back and passes −1 ms. On each, the command and the integral hold for one tick, exactly, and the plant moves on. From 100 ms the controller misses 49 ticks: the actuator holds the last command, flat on the plot, while the plant keeps moving. At 149 ms it runs with dt = 50 ms. That dt is valid, so the integral takes the whole 50 ms in one step and jumps by 0.07, and the command steps down to match the new error. Pass criterion: on the two faulted ticks, the output and the integral change by exactly 0.

  1. setpoint 0.5
  2. duplicated tick: dt = 0
  3. clock steps back: dt = −1 ms
  4. the controller misses 49 ticks
  5. it runs again, with dt = 50 ms
  • ✓ passBB-T1 output_and_integral_change_on_faulted_ticks = 0 (<= 0), computed by the scenario harness

The controller cannot tell a late tick from a slow loop. A gap like the one at 100 ms is the scheduler’s to detect: an overrun counter, or a watchdog that resets the controller when the gap is longer than the loop tolerates.

A rejected call also leaves a debt. The controller keeps the measurement of the last call it accepted, so the next dt must be the time since that call. A scheduler that measures dt from the rejected call passes too short an interval: the derivative divides the change since the last accepted sample by part of the time it took, and spikes, and the integral misses the difference. The replay’s scheduler makes that mistake. The tick after each fault passes 1 ms, although 2 ms have passed since the last accepted call. With no D term here, the only cost is 1 ms of integration; with one, the measured rate would double for that tick.

Pid<Real> uses only + - * /, <, and construction from an integer, so it works unchanged with custom arithmetic. The test suite runs the control law and a full closed loop (saturation, anti-windup, filtered derivative) in double, float, posit<32,2>, posit<16,1>, and IEEE-single cfloat<32,8>, comparing each against the double reference.